{"id":30827,"date":"2024-08-28T12:20:01","date_gmt":"2024-08-28T10:20:01","guid":{"rendered":"https:\/\/www.lt-gasetechnik.de\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/"},"modified":"2024-08-28T12:20:01","modified_gmt":"2024-08-28T10:20:01","slug":"sil-2-low-temperature-protection-shutdown-with-evaporator-change-over","status":"publish","type":"post","link":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/","title":{"rendered":"SIL 2 Low Temperature Protection \/ Shutdown with Evaporator Change Over"},"content":{"rendered":"<p data-pm-slice=\"1 1 []\">\n<p>&nbsp;<\/p>\n<ul class=\"wkDKeDt76JBvMocE5JrK\">\n<li>Automatic Evaporator Change Over with SIL-2 low temperature shut off in DN65 PN40 for nitrogen<\/li>\n<li>Adjustable change of air evaporators via time interval, media temperature and pressure drop. Touchscreen, flashlight\/horn and 2 potential-free contacts for message forwarding <\/li>\n<li>System consisting of o 2 pneumatic stainless steel ball valves for changeover o 3 resistance thermometers o Pneumatically actuated shut-off ball valve o 3 manual, shut-off and bypass ball valves<\/li>\n<li>Documentation according to PED (Pressure Equipment Directive) incl. SIL circle Calculation according to classification level of functional safety #SIL 2 (SIL= #safety requirement level, #safety level or safety integrity level, SIL for short) <\/li>\n<li>Plug + Play: Height-adjustable traverse for simple on-site installation of supply voltage, control medium and pipes<\/li>\n<\/ul>\n<p>&nbsp; If safe shutdown of the gas supply is required for brittle fracture monitoring when the evaporator is overrun, many customers rely on a standard low temperature protection system (#LTPS) from LT GASETECHNIK. Equipment based on the &#8220;Cryogenic evaporator systems &#8211; Prevention of brittle fracture of equipment and piping&#8221; document IGC Doc. 133 \/ 05.   &nbsp;<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-medium wp-image-30810\" src=\"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-300x225.jpg 300w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-1024x768.jpg 1024w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-768x576.jpg 768w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-1536x1152.jpg 1536w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-1920x1440.jpg 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><img decoding=\"async\" class=\"aligncenter size-medium wp-image-30814\" src=\"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/PID-300x139.jpg\" alt=\"\" width=\"300\" height=\"139\" srcset=\"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/PID-300x139.jpg 300w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/PID-1024x476.jpg 1024w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/PID-768x357.jpg 768w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/PID.jpg 1166w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><img decoding=\"async\" class=\"aligncenter size-medium wp-image-30818\" src=\"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7481-b-225x300.jpg\" alt=\"\" width=\"225\" height=\"300\" srcset=\"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7481-b-225x300.jpg 225w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7481-b-768x1024.jpg 768w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7481-b-1152x1536.jpg 1152w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7481-b-1536x2048.jpg 1536w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7481-b-1440x1920.jpg 1440w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7481-b-scaled.jpg 1920w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><img decoding=\"async\" class=\"aligncenter size-medium wp-image-30822\" src=\"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7486-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7486-300x225.jpg 300w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7486-1024x768.jpg 1024w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7486-768x576.jpg 768w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7486-1536x1152.jpg 1536w, https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7486-1920x1440.jpg 1920w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; Automatic Evaporator Change Over with SIL-2 low temperature shut off in DN65 PN40 for nitrogen Adjustable change of air evaporators via time interval, media temperature and pressure drop. Touchscreen, flashlight\/horn and 2 potential-free contacts for message forwarding System consisting of o 2 pneumatic stainless steel ball valves for changeover o 3 resistance thermometers o [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[208],"tags":[1103,1105,555,1104,541],"class_list":["post-30827","post","type-post","status-publish","format-standard","hentry","category-air-evaporator-switch-over","tag-alu-en","tag-low-temperature-protection","tag-sil-en","tag-tts-en","tag-vaporizer-switchover"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SIL 2 Low Temperature Protection \/ Shutdown with Evaporator Change Over - LT GASETECHNIK<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SIL 2 Low Temperature Protection \/ Shutdown with Evaporator Change Over - LT GASETECHNIK\" \/>\n<meta property=\"og:description\" content=\"&nbsp; Automatic Evaporator Change Over with SIL-2 low temperature shut off in DN65 PN40 for nitrogen Adjustable change of air evaporators via time interval, media temperature and pressure drop. Touchscreen, flashlight\/horn and 2 potential-free contacts for message forwarding System consisting of o 2 pneumatic stainless steel ball valves for changeover o 3 resistance thermometers o [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/\" \/>\n<meta property=\"og:site_name\" content=\"LT GASETECHNIK\" \/>\n<meta property=\"article:published_time\" content=\"2024-08-28T10:20:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-300x225.jpg\" \/>\n<meta name=\"author\" content=\"Alexander Hanf\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alexander Hanf\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/\"},\"author\":{\"name\":\"Alexander Hanf\",\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/#\\\/schema\\\/person\\\/d9db0cad8ac27bf62f95b66b4b8fbfd4\"},\"headline\":\"SIL 2 Low Temperature Protection \\\/ Shutdown with Evaporator Change Over\",\"datePublished\":\"2024-08-28T10:20:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/\"},\"wordCount\":174,\"publisher\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/IMG_7483-300x225.jpg\",\"keywords\":[\"ALU\",\"Low temperature protection\",\"SIL\",\"TTS\",\"Vaporizer switchover\"],\"articleSection\":[\"Air evaporator switch-over\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/\",\"url\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/\",\"name\":\"SIL 2 Low Temperature Protection \\\/ Shutdown with Evaporator Change Over - LT GASETECHNIK\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/IMG_7483-300x225.jpg\",\"datePublished\":\"2024-08-28T10:20:01+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/IMG_7483-300x225.jpg\",\"contentUrl\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/IMG_7483-300x225.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/2024\\\/08\\\/28\\\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SIL 2 Low Temperature Protection \\\/ Shutdown with Evaporator Change Over\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/\",\"name\":\"LT GASETECHNIK\",\"description\":\"beyond standards\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/#organization\",\"name\":\"LT GASETECHNIK\",\"url\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/lt-gasetechnik-logo-60x330-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/lt-gasetechnik-logo-60x330-1.jpg\",\"width\":330,\"height\":60,\"caption\":\"LT GASETECHNIK\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/#\\\/schema\\\/person\\\/d9db0cad8ac27bf62f95b66b4b8fbfd4\",\"name\":\"Alexander Hanf\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db2b524fb591574d36b6f1c5af0218f7a6af4a228530c02a586d1be61f1d05c4?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db2b524fb591574d36b6f1c5af0218f7a6af4a228530c02a586d1be61f1d05c4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/db2b524fb591574d36b6f1c5af0218f7a6af4a228530c02a586d1be61f1d05c4?s=96&d=mm&r=g\",\"caption\":\"Alexander Hanf\"},\"sameAs\":[\"https:\\\/\\\/www.lt-gasetechnik.de\"],\"url\":\"https:\\\/\\\/www.lt-gasetechnik.de\\\/en\\\/author\\\/alexander-c-hanf\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SIL 2 Low Temperature Protection \/ Shutdown with Evaporator Change Over - LT GASETECHNIK","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/","og_locale":"en_US","og_type":"article","og_title":"SIL 2 Low Temperature Protection \/ Shutdown with Evaporator Change Over - LT GASETECHNIK","og_description":"&nbsp; Automatic Evaporator Change Over with SIL-2 low temperature shut off in DN65 PN40 for nitrogen Adjustable change of air evaporators via time interval, media temperature and pressure drop. Touchscreen, flashlight\/horn and 2 potential-free contacts for message forwarding System consisting of o 2 pneumatic stainless steel ball valves for changeover o 3 resistance thermometers o [&hellip;]","og_url":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/","og_site_name":"LT GASETECHNIK","article_published_time":"2024-08-28T10:20:01+00:00","og_image":[{"url":"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-300x225.jpg","type":"","width":"","height":""}],"author":"Alexander Hanf","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alexander Hanf","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/#article","isPartOf":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/"},"author":{"name":"Alexander Hanf","@id":"https:\/\/www.lt-gasetechnik.de\/en\/#\/schema\/person\/d9db0cad8ac27bf62f95b66b4b8fbfd4"},"headline":"SIL 2 Low Temperature Protection \/ Shutdown with Evaporator Change Over","datePublished":"2024-08-28T10:20:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/"},"wordCount":174,"publisher":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/#organization"},"image":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-300x225.jpg","keywords":["ALU","Low temperature protection","SIL","TTS","Vaporizer switchover"],"articleSection":["Air evaporator switch-over"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/","url":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/","name":"SIL 2 Low Temperature Protection \/ Shutdown with Evaporator Change Over - LT GASETECHNIK","isPartOf":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/#primaryimage"},"image":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/#primaryimage"},"thumbnailUrl":"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-300x225.jpg","datePublished":"2024-08-28T10:20:01+00:00","breadcrumb":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/#primaryimage","url":"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-300x225.jpg","contentUrl":"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2024\/08\/IMG_7483-300x225.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.lt-gasetechnik.de\/en\/2024\/08\/28\/sil-2-low-temperature-protection-shutdown-with-evaporator-change-over\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.lt-gasetechnik.de\/en\/"},{"@type":"ListItem","position":2,"name":"SIL 2 Low Temperature Protection \/ Shutdown with Evaporator Change Over"}]},{"@type":"WebSite","@id":"https:\/\/www.lt-gasetechnik.de\/en\/#website","url":"https:\/\/www.lt-gasetechnik.de\/en\/","name":"LT GASETECHNIK","description":"beyond standards","publisher":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lt-gasetechnik.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.lt-gasetechnik.de\/en\/#organization","name":"LT GASETECHNIK","url":"https:\/\/www.lt-gasetechnik.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.lt-gasetechnik.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2020\/06\/lt-gasetechnik-logo-60x330-1.jpg","contentUrl":"https:\/\/www.lt-gasetechnik.de\/wp-content\/uploads\/2020\/06\/lt-gasetechnik-logo-60x330-1.jpg","width":330,"height":60,"caption":"LT GASETECHNIK"},"image":{"@id":"https:\/\/www.lt-gasetechnik.de\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.lt-gasetechnik.de\/en\/#\/schema\/person\/d9db0cad8ac27bf62f95b66b4b8fbfd4","name":"Alexander Hanf","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/db2b524fb591574d36b6f1c5af0218f7a6af4a228530c02a586d1be61f1d05c4?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/db2b524fb591574d36b6f1c5af0218f7a6af4a228530c02a586d1be61f1d05c4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/db2b524fb591574d36b6f1c5af0218f7a6af4a228530c02a586d1be61f1d05c4?s=96&d=mm&r=g","caption":"Alexander Hanf"},"sameAs":["https:\/\/www.lt-gasetechnik.de"],"url":"https:\/\/www.lt-gasetechnik.de\/en\/author\/alexander-c-hanf\/"}]}},"_links":{"self":[{"href":"https:\/\/www.lt-gasetechnik.de\/en\/wp-json\/wp\/v2\/posts\/30827","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lt-gasetechnik.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lt-gasetechnik.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lt-gasetechnik.de\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lt-gasetechnik.de\/en\/wp-json\/wp\/v2\/comments?post=30827"}],"version-history":[{"count":0,"href":"https:\/\/www.lt-gasetechnik.de\/en\/wp-json\/wp\/v2\/posts\/30827\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.lt-gasetechnik.de\/en\/wp-json\/wp\/v2\/media?parent=30827"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lt-gasetechnik.de\/en\/wp-json\/wp\/v2\/categories?post=30827"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lt-gasetechnik.de\/en\/wp-json\/wp\/v2\/tags?post=30827"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}