High-precision redundant oxygen/nitrogen gas mixers

1024 446 Alexander Hanf

LT gas mixer type advanced with mass flow controllers (MFC) for mixing O2 with N2. Performance range of each gas mixer: 10… 65 Nm³/h.

The customer process from the electronics industry requires a high accuracy of +/- 0.5%, which LT GASETECHNIK guarantees. On the basis of pressure monitoring, the two gas mixers change-over automatically, so that redundancy is granted.

Two gas mixers type advanced

A separate output temperature monitoring ensures that the downstream steel pipes are protected against brittle breakage.

The gas mixture result is monitored by Southland’s integrated, innovative in-line gas analyzer with electrochemical measuring cell and documented via interface in the gas mixer control system.

Electrochemical oxygen measuring cell, measuring range 0…1% oxygen in gas mixture.

Do you have tasks related to the high-precision mixing and analysis of gases? We are happy to advise you: info@lt-gasetechnik.com

Privacy settings

When you visit our website, it may store information about your browser from certain services, usually in the form of cookies. You can change your privacy settings here. Please note that blocking some types of cookies may affect your experience on our website and the services we offer.

For performance and security reasons we use Cloudflare.
required cookies

Click here to enable/disable the tracking code of Google Analytics

Click here to enable/disable Google Maps

Click here to enable/disable video embedding
Our website uses cookies, mainly from third parties. Please define your privacy settings and/or agree to the use of cookies.